This appendix provides physical, electrical, and environmental specifications for the Vault rack and SCSIBox 2.
Table A-1 lists the Vault specifications.
Table A-1. Vault Rack Specifications
Parameters | Characteristics |
---|---|
Dimensions (Height x Width x Depth) | 62.3 inches (158 cm) x 27 inches (69 cm) x 48 inches (122 cm) |
Weight | 320 lb (145 kg)—without drive boxes or drives 1200 lb (544 kg)—fully loaded |
Electrical |
|
Voltage | 208 to 230 VAC, single phase |
Frequency Range (single phase) | 50 Hz (minimum) |
Current | 220 VAC at 16 amps, single phase |
Connector | NEMA L6-30P, 2-P, 3-2 30A, 250V (U.S., Canada, and
Japan); |
Safety and Regulatory |
|
UL | Listed under UL 478–Data Processing Equipment, Electronic |
Canadian Standards Association (CSA) | Certified under CSA 220-M1986–Information Processing and Business Equipment |
TUV | Licensed under CENELEC European Norm EN 60 950/09.87 |
EMI | FCC Class A |
Product Model No. | CMN A012B |
Environmental |
|
Temperature | 5 to 35 degrees C at sea level (operating) |
Relative Humidity | 20 to 80%, noncondensing (operating) |
No. of SCSI Boxes | 1 to 12 |
No. of Drives | Up to 96 half-height drives or up to 48 full-height drives |
Peripherals Supported (SCSI only) | 780 MB Fast 2.0 GB half-height |
Table A-2 lists the SCSIBox 2 specifications.
Table A-2. SCSIBox 2 Specifications
Parameters | Characteristics |
---|---|
Dimensions (Height x Width x Depth) | 7.5 inches (19.05 cm) x 17.25 inches (43.82 cm) x 20.5 inches (52.07 cm) |
Weight | 35 lb (15.88 kg)–without drives |
Device Weight | 4.5 to 7.6 lb (2.04 to 3.45 kg) |
Electrical |
|
Power Supplies | 5 VDC at 16 A |
Voltage | 208 to 230 VAC |
Frequency | 50/60 Hz, single phase |
Line Current | 1.5 A (maximum) |
Safety and Regulatory |
|
UL | UL 1950 |
CSA | CSA C22.2 No. 154-M1983 or CAN/CSA-C22.2 No. 950-M89 |
TUV | Licensed under CENELEC European Norm EN 60 950/09.87 |
EMI | FCC, Part 15, Class A |
Product Model No. | CMN AS02 |
Environmental |
|
Temperature | 5 to 35 degrees C at sea level (operating) |
Relative Humidity | 20 to 80%, noncondensing (operating) |