Specifications


OCTANE Workstation - Physical Environment Specifications

Element Specification
OCTANE workstation dimensions 16.25" H x 11.0" W x 13.25" D
14.75" D (depth in localized are of power supply)
16.25" D (depth in localized area of optional PCI module)
Voltage and Frequency 100 - 240 VAC, 50-60 Hz, 10-4.2A, 850W
Ambient Temperature +13C to +35C (operating)
-10C to +65C (non-operating
Relative Humidity 10% to 80% operating (no condensation)
10% to 95% non-operating (no condensation)
Heat Dissipation 2400 BTU/hour
Altitude 10,000' (operating)
40,000' (non-operating)
Vibration 0.02" displacement, 5-19 Hz;
0.35 G, 19 - 500 Hz



PCI Module Power Specifications

Total power for the PCI module (the sum of the power for all boards from all power supply rails) must not exceed 45.0W (average 15.0W per board).


The OCTANE PCI module is a 5V system environment.

Power Supply Rail Maximum Current Maximum Power
3.3V 10.0A 33.0W
5.0V 9.0A 45.0W
12.0V 1.5A 12.0W
-12.0V 0.3A 3.6W


Note: For additional information, see Section 4.3.4.1, in the chapter called "Power Requirements," in the PCI Local Bus Specification, Rev.2.1, June 1995 (PCI Special Interest Group, Portland, OR).